DKS: terminal pressure switches that monitor pressure in both lines at the end of a two-line circuit. Via a control unit they signal when end pressure is reached and enable automatic system operation.
Features
- DKS 2: one manometer for both lines, special fitting for 28 x 4 mm pipe
- DKS 3, DKS 4: one manometer per line, through-way connection G3/8
- Switching range 10…100 or 40…320 bar (DKS 2/3), 40…400 bar (DKS 4)
- Supply 230 V AC or 220 V DC, IP65
- Grease up to NLGI 2 or oil min. 50 mm²/s; -20…+80 °C
- Inlet G3/8 or M16 x 1.5; weight 3.8 kg
Applications
End-of-line pressure control in two-line central lubrication systems.